112 ECT board: what it holds

112 ECT board carries 112 lb per inch of edge in an edge crush test. Built into a 12 × 12 × 12 in AAC triple wall box, the simplified McKee formula puts its compression strength near 3,320 lbf.

Estimated box compression by flute

Simplified McKee BCT, lbf, empty box
Inside size, inAAC triple wall
8 × 6 × 42,536
10 × 8 × 62,875
12 × 12 × 123,320
14 × 10 × 83,320
16 × 12 × 103,586
18 × 12 × 123,712
18 × 18 × 184,066
20 × 16 × 144,066
24 × 18 × 184,392
24 × 24 × 244,695

Working load after storage

McKee gives the strength of a new, dry box. In storage it loses strength. Using Packgent's default storage losses (an assumption, see method), this is the most the bottom AAC triple wall box can carry at each age:

Allowed load on the bottom box, lbf (AAC triple wall, 112 ECT)
Inside size, in0 days10 days30 days90 days180 days
8 × 62,5361,5981,5211,3951,268
10 × 82,8751,8111,7251,5811,438
12 × 123,3202,0921,9921,8261,660
14 × 103,3202,0921,9921,8261,660
16 × 123,5862,2592,1521,9721,793
18 × 123,7122,3392,2272,0421,856

Neighbouring grades

GradeECT changeBCT change, same flute and size
90 ECT-22 lb/in-20%

In McKee, BCT scales directly with ECT, so the percentage change in strength equals the change in ECT.

Freight rule limits

NMFC Item 222 ties each grade to a maximum gross weight and size for LTL shipping. Packgent has not published those limits yet because they could not be checked against the current tariff. See the Item 222 page for status.